Digital Database for Screening Mammography

Overview of Volume: cancer_03


This table contains links to overview pages for the cases in this volume. Each overview page contains the ics file, "thumbnails" of the images associated with the case, and the overlay markings of the abnormalities. The "thumbnail" images are meant for visual browsing of the cases only, and are not suitable for any form of experimental work. The thumbnail images were blurred, subsampled, sharpened and converted to eight bits per pixel. Thus, they contain artifacts introduced by this processing (i.e., aliasing, ringing, re-quantization, clipping etc.). Any experimental work should start with the full raw images for the case.

Each case in this volume of cancer cases has at least one path-proven cancer. Some cases contain more than one cancer in one breast, a cancer in each breast, or a cancer along with other abnormal/suspicious regions. The outlines of all regions have been transcribed from markings made by an experienced mammographer. In almost all cases, an abnormality is visible in both views of the breast. However, there are a cases where an abnormality seen in one view is not visible in the other view. This is most often due to the fact that the CC and MLO views do not image exactly the same tissue, but in some cases the abnormality may simply not present any visible signs in one view.

The "ics" header file contains the following information. The "DATE_OF_STUDY" field gives the date that the mammogram was performed. The "PATIENT_AGE" field gives the age of the patient at the time that the mammogram was performed. The "DENSITY" field gives an ACR BI-RADS breast density rating for the case, as assigned by an experienced mammographer. The "DIGITIZER" field indicates the equipment used to digitize the mammogram films. The "LEFT_CC," "LEFT_MLO," RIGHT_CC," and "RIGHT_MLO" fields specify the size of the corresponding images and whether or not a file exists for the overlay of abnormality outlines. The "FILM," "FILM_TYPE," "SEQUENCE" and "DATE_DIGITIZED" fields should be disregarded. They are being maintained for compatibility with earlier versions of the database, but do not contain useful information.

The individual overlay files contain keywords to describe each abnormality. They also contain an ACR BI-RADS assessment code for each abnormality. And they contain a mammographer-assigned "subtlety rating" on a scale of 1 to 5, where 1 is "subtle" and 5 is "obvious." The mammographer was not constrained to provide the same keyword description for a given abnormality in each view. Unusual objects (e.g., pacemaker, breast implant) may be visible in some images. These are not identified by an overlay file.

We strongly encourage that whenever research results are presented using cases from this database, a histogram of the subtlety rating of the images used in the research also be presented.

You can order the complete volume on tape. Click here for an order form. Please note that you should be using the lastest version of DDSMView to view the complete cases. You can get it here or from our ftp site (figment.csee.usf.edu) in the directory "pub/DDSM/software/bin" using anonymous ftp.

case1000 case1002 case1003 case1004 case1005 case1006 case1007 case1008
case1009 case1011 case1012 case1014 case1015 case1016 case1017 case1019
case1020 case1021 case1022 case1023 case1024 case1025 case1026 case1027
case1029 case1030 case1031 case1032 case1033 case1035 case1036 case1037
case1039 case1040 case1041 case1042 case1043 case1044 case1046 case1047
case1048 case1049 case1050 case1051 case1052 case1053 case1055 case1056
case1057 case1058 case1059 case1060 case1061 case1062 case1063 case1064
case1065 case1066 case1070 case1072 case1078 case1080 case1083 case1084
case1085 case1086