Digital Database for Screening Mammography

Overview of Volume: cancer_07


This table contains links to overview pages for the cases in this volume. Each overview page contains the ics file, "thumbnails" of the images associated with the case, and the overlay markings of the abnormalities. The "thumbnail" images are meant for visual browsing of the cases only, and are not suitable for any form of experimental work. The thumbnail images were blurred, subsampled, sharpened and converted to eight bits per pixel. Thus, they contain artifacts introduced by this processing (i.e., aliasing, ringing, re-quantization, clipping etc.). Any experimental work should start with the full raw images for the case.

Each case in this volume of cancer cases has at least one path-proven cancer. Some cases contain more than one cancer in one breast, a cancer in each breast, or a cancer along with other abnormal/suspicious regions. The outlines of all regions have been transcribed from markings made by an experienced mammographer. In almost all cases, an abnormality is visible in both views of the breast. However, there are a cases where an abnormality seen in one view is not visible in the other view. This is most often due to the fact that the CC and MLO views do not image exactly the same tissue, but in some cases the abnormality may simply not present any visible signs in one view.

The "ics" header file contains the following information. The "DATE_OF_STUDY" field gives the date that the mammogram was performed. The "PATIENT_AGE" field gives the age of the patient at the time that the mammogram was performed. The "DENSITY" field gives an ACR BI-RADS breast density rating for the case, as assigned by an experienced mammographer. The "DIGITIZER" field indicates the equipment used to digitize the mammogram films. The "LEFT_CC," "LEFT_MLO," RIGHT_CC," and "RIGHT_MLO" fields specify the size of the corresponding images and whether or not a file exists for the overlay of abnormality outlines. The "FILM," "FILM_TYPE," "SEQUENCE" and "DATE_DIGITIZED" fields should be disregarded. They are being maintained for compatibility with earlier versions of the database, but do not contain useful information.

The individual overlay files contain keywords to describe each abnormality. They also contain an ACR BI-RADS assessment code for each abnormality. And they contain a mammographer-assigned "subtlety rating" on a scale of 1 to 5, where 1 is "subtle" and 5 is "obvious." The mammographer was not constrained to provide the same keyword description for a given abnormality in each view. Unusual objects (e.g., pacemaker, breast implant) may be visible in some images. These are not identified by an overlay file.

We strongly encourage that whenever research results are presented using cases from this database, a histogram of the subtlety rating of the images used in the research also be presented.

Please note that you should be using the lastest version of DDSMView to view the complete cases. You can get it here or from our ftp site (figment.csee.usf.edu) in the directory "pub/DDSM/software/bin" using anonymous ftp.

case1114 case1116 case1118 case1127 case1129 case1130 case1132 case1134
case1135 case1142 case1143 case1146 case1147 case1149 case1159 case1160
case1166 case1204 case1207 case1213 case1214 case1215 case1217 case1218
case1219 case1220 case1223 case1224 case1227 case1228 case1232 case1233
case1234 case1235 case1237 case1238 case1239 case1240 case1244 case1245
case1247 case1248 case1249 case1253 case1255 case1256 case1257 case1258
case1260 case1261 case1262 case1263