Digital Database for Screening Mammography

Overview of Volume: cancer_11


This table contains links to overview pages for the cases in this volume. Each overview page contains the ics file, "thumbnails" of the images associated with the case, and the overlay markings of the abnormalities. The "thumbnail" images are meant for visual browsing of the cases only, and are not suitable for any form of experimental work. The thumbnail images were blurred, subsampled, sharpened and converted to eight bits per pixel. Thus, they contain artifacts introduced by this processing (i.e., aliasing, ringing, re-quantization, clipping etc.). Any experimental work should start with the full raw images for the case.

Each case in this volume of cancer cases has at least one path-proven cancer. Some cases contain more than one cancer in one breast, a cancer in each breast, or a cancer along with other abnormal/suspicious regions. The outlines of all regions have been transcribed from markings made by an experienced mammographer. In almost all cases, an abnormality is visible in both views of the breast. However, there are a cases where an abnormality seen in one view is not visible in the other view. This is most often due to the fact that the CC and MLO views do not image exactly the same tissue, but in some cases the abnormality may simply not present any visible signs in one view.

The "ics" header file contains the following information. The "DATE_OF_STUDY" field gives the date that the mammogram was performed. The "PATIENT_AGE" field gives the age of the patient at the time that the mammogram was performed. The "DENSITY" field gives an ACR BI-RADS breast density rating for the case, as assigned by an experienced mammographer. The "DIGITIZER" field indicates the equipment used to digitize the mammogram films. The "LEFT_CC," "LEFT_MLO," RIGHT_CC," and "RIGHT_MLO" fields specify the size of the corresponding images and whether or not a file exists for the overlay of abnormality outlines. The "FILM," "FILM_TYPE," "SEQUENCE" and "DATE_DIGITIZED" fields should be disregarded. They are being maintained for compatibility with earlier versions of the database, but do not contain useful information.

The individual overlay files contain keywords to describe each abnormality. They also contain an ACR BI-RADS assessment code for each abnormality. And they contain a mammographer-assigned "subtlety rating" on a scale of 1 to 5, where 1 is "subtle" and 5 is "obvious." The mammographer was not constrained to provide the same keyword description for a given abnormality in each view. Unusual objects (e.g., pacemaker, breast implant, skin marker) may be visible in some images. These are not identified by an overlay file.

We strongly encourage that whenever research results are presented using cases from this database, a histogram of the subtlety rating of the images used in the research also be presented.

Please note that you should be using the lastest version of DDSMView to view the complete cases. You can get it here or from our ftp site (figment.csee.usf.edu) in the directory "pub/DDSM/software/bin" using anonymous ftp.

case1183 case1222 case1236 case1252 case1329 case1531 case1576 case1614
case1632 case1635 case1636 case1637 case1652 case1657 case1658 case1661
case1663 case1671 case1672 case1673 case1674 case1675 case1676 case1677
case1678 case1693 case1694 case1695 case1696 case1697 case1701 case1720
case1721 case1722 case1723 case1724 case1725 case1726 case1727 case1728
case1729 case1730 case1731 case1766 case1772 case1780 case1790 case1804
case1816 case1817 case1819 case1820 case1821 case1823 case1824 case1825
case1826 case1827 case1828