Digital Database for Screening Mammography

Overview of Volume: cancer_01


This table contains links to overview pages for the cases in this volume. Each overview page contains the ics file, "thumbnails" of the images associated with the case, and the overlay markings of the abnormalities. The "thumbnail" images are meant for visual browsing of the cases only, and are not suitable for any form of experimental work. The thumbnail images were blurred, subsampled, sharpened and converted to eight bits per pixel. Thus, they contain artifacts introduced by this processing (i.e., aliasing, ringing, re-quantization, clipping etc.). Any experimental work should start with the full raw images for the case.

Each case in this volume of cancer cases has at least one path-proven cancer. Some cases contain more than one cancer in one breast, a cancer in each breast, or a cancer along with other abnormal/suspicious regions. The outlines of all regions have been transcribed from markings made by an experienced mammographer. In almost all cases, an abnormality is visible in both views of the breast. However, there are a cases where an abnormality seen in one view is not visible in the other view. This is most often due to the fact that the CC and MLO views do not image exactly the same tissue, but in some cases the abnormality may simply not present any visible signs in one view.

The "ics" header file contains the following information. The "DATE_OF_STUDY" field gives the date that the mammogram was performed. The "PATIENT_AGE" field gives the age of the patient at the time that the mammogram was performed. The "DENSITY" field gives an ACR BI-RADS breast density rating for the case, as assigned by an experienced mammographer. The "DIGITIZER" field indicates the equipment used to digitize the mammogram films. The "LEFT_CC," "LEFT_MLO," RIGHT_CC," and "RIGHT_MLO" fields specify the size of the corresponding images and whether or not a file exists for the overlay of abnormality outlines. The "FILM," "FILM_TYPE," "SEQUENCE" and "DATE_DIGITIZED" fields should be disregarded. They are being maintained for compatibility with earlier versions of the database, but do not contain useful information.

The individual overlay files contain keywords to describe each abnormality. They also contain an ACR BI-RADS assessment code for each abnormality. And they contain a mammographer-assigned "subtlety rating" on a scale of 1 to 5, where 1 is "subtle" and 5 is "obvious." The mammographer was not constrained to provide the same keyword description for a given abnormality in each view. Unusual objects (e.g., pacemaker, breast implant) may be visible in some images. These are not identified by an overlay file.

We strongly encourage that whenever research results are presented using cases from this database, a histogram of the subtlety rating of the images used in the research also be presented.

You can order the complete volume on tape. Click here for an order form. Please note that you should be using the lastest version of DDSMView to view the complete cases. You can get it here or from our ftp site (figment.csee.usf.edu) in the directory "pub/DDSM/software/bin" using anonymous ftp.

case0001 case0002 case0003 case0004 case0006 case0007 case0009 case0010
case0011 case0012 case0014 case0015 case0016 case0017 case0019 case0020
case3001 case3003 case3005 case3007 case3008 case3009 case3010 case3012
case3013 case3016 case3017 case3018 case3019 case3020 case3021 case3022
case3023 case3025 case3026 case3027 case3030 case3032 case3033 case3037
case3038 case3041 case3042 case3044 case3045 case3046 case3047 case3049
case3051 case3055 case3057 case3058 case3059 case3062 case3064 case3065
case3066 case3068 case3071 case3072 case3073 case3076 case3079 case3080
case3081 case3082 case3083 case3084 case3086